Thermostat Model: Moes BRT-100 Radiator Thermostat Alteration under the nRF52 BT Mesh. BRT-100 based on TUYA TYZS3 and ZT5. MCU supported following DPID: Query the Device Initialization Status command results: 0x1 ENUM Mode: 0 - programming, 1 - manual, 2 - temporary manual, 3 - holiday 0x2 VALUE Desired temperature (32) T = Val 0x3 VALUE Current temperature (230) T = (Val / 10) 0x4 BOOL Boost heating [Rapid heating] 0x5 VALUE Boost heating countdow (min) 0x7 ENUM Status: 0 - нагрев, 1 - пауза 0x8 BOOL A2 Open Window Detection (bool: false - close, true - open) [Window check] 0x9 ENUM Window state: 0 - open, 1 - close 0xE VALUE Battery status - percents (0 - 100) 0xD BOOL Child lock (true - lock, false - unlock) 0x65 RAW Schedule: 12 records by 3 bytes 0x67 VALUE A7 Forced heating countdown [BoostTime] 0x68 VALUE Valve ratio (opening range 0 - 100) 0x69 VALUE A1 Temperature compensation (-9 ~ 9) [FillerTemp] 0x6A BOOL AA Energy saving mode [Eco_Mode] 0x6B VALUE AB Energy saving mode temperature [Eco_Temp] 0x6C VALUE A6 Max. temp [Upper SetTemp Limit] 0x6D VALUE A5 Min. temp [Lower SetTemp Limit]